Filters
Source Meters
-
0₫| /
Keithley 2600 2 Ch Sourcemeter, 80 W, ±100 nA → ±10 A, ±100 mV → ±40 V [2602B]; 768-3419
Keithley.THÔNG SỐ KỸ THUẬT: Series 2600 Sourcemeter Function Current Resistance Voltage Measure, Current Voltage Source Number of Channels...
View full details -
0₫| /
Keysight Technologies B2900B 1 Ch Sourcemeter, 31.8 W, 1 μV → 210 V [B2901B]; 210-0283
Keysight Technologies.THÔNG SỐ KỸ THUẬT: Series B2900B Sourcemeter Function Measure Voltage & Current Number of Channels 1 Source Voltage Range...
View full details -
0₫| /
Keysight Technologies B2900B 2 Ch Sourcemeter, 31.8 W, 100 nV → 210 V [B2912B]; 210-0288
Keysight Technologies.THÔNG SỐ KỸ THUẬT: Series B2900B Sourcemeter Function Measure Voltage & Current Number of Channels 2 Source Voltage Range...
View full details -
0₫| /
Keysight Technologies B2900BL 1 Ch Sourcemeter, 31.8 W, 1 μV → 21 V [B2901BL]; 210-0284
Keysight Technologies.THÔNG SỐ KỸ THUẬT: Series B2900BL Sourcemeter Function Measure Voltage & Current Number of Channels 1 Source Voltage Rang...
View full details -
0₫| /
Keysight Technologies B2900BL 1 Ch Sourcemeter, 31.8 W, 1 μV → 210 V [B2910BL]; 210-0286
Keysight Technologies.THÔNG SỐ KỸ THUẬT: Series B2900BL Sourcemeter Function Measure Voltage & Current Number of Channels 1 Source Voltage Rang...
View full details -
0₫| /
Keysight Technologies B2900B 1 Ch Sourcemeter, 31.8 W, 100 nV → 210 V [B2911B]; 210-0287
Keysight Technologies.THÔNG SỐ KỸ THUẬT: Series B2900B Sourcemeter Function Measure Voltage & Current Number of Channels 1 Source Voltage Range...
View full details -
0₫| /
Keysight Technologies B2900B 2 Ch Sourcemeter, 31.8 W, 1 μV → 210 V [B2902B]; 210-0285
Keysight Technologies.THÔNG SỐ KỸ THUẬT: Series B2900B Sourcemeter Function Measure Voltage & Current Number of Channels 2 Source Voltage Range...
View full details -
0₫| /
Keithley 2606B Sourcemeter, 4 Ch, 1 KΩ 100 nA → 3 A 100 → 240 V ac 20.2 W, 2600B Series [2606B]; 176-5836
KeithleyTHÔNG SỐ KỸ THUẬT Series 2600B Sourcemeter Function SMU Instrument Number of Channels 4 Source Voltage Range 100 → 240 V ac Source ...
View full details -
0₫| /
Keithley 2461 Sourcemeter <2 Ω to >200 MΩ 10 (Pulsed Output) A, 7 (DC Output) A 200 mV → 100 V 1000 W [2461]; 918-1420
Keithley.THÔNG SỐ KỸ THUẬT: Series 2400 Sourcemeter Function Current, Resistance, Voltage Number of Channels 1 Source Voltage Range 20...
View full details -
0₫| /
2470 High Voltage SourceMeter [2470]; 188-8377
KeithleyTHÔNG SỐ KỸ THUẬT Series 2400 Sourcemeter Function Current, Resistance, Voltage Number of Channels 1 Source Voltage Range 200 mV → 10...
View full details -
0₫| /
Keithley 2401 Sourcemeter, 1 Ch, 0.2 Ω → 200 MΩ ±1 μA → ±1 A ±200 mV → ±20 V 20 W [2401]; 758-8857
KeithleyTHÔNG SỐ KỸ THUẬT Series 2400 Sourcemeter Function Current Resistance Voltage Measure, Current Voltage Source Number of Channels 1 So...
View full details -
0₫| /
Keysight Technologies B2912A Sourcemeter, 2 Ch, 2 Ω → 200 MΩ 10.5 (Pulsed Output) A, 3 (DC Output) A [B2912A]; 888-2361
Keysight TechnologiesTHÔNG SỐ KỸ THUẬT Series B2900A Sourcemeter Function Current Measure, Voltage Measure Number of Channels 2 Source Voltage Range 210 (...
View full details -
0₫| /
Keysight Technologies B2902A Sourcemeter, 2 Ch, 2 Ω → 200 MΩ 10.5 (Pulsed Output) A, 3 (DC Output) A [B2902A]; 888-2358
Keysight TechnologiesTHÔNG SỐ KỸ THUẬT Series B2900A Sourcemeter Function Current Measure, Voltage Measure Number of Channels 2 Source Voltage Range 210 (...
View full details -
0₫| /
Keysight Technologies B2901A Sourcemeter, 1 Ch, 2 Ω → 200 MΩ 10.5 (Pulsed Output) A, 3 (DC Output) A [B2901A]; 888-2355
Keysight TechnologiesTHÔNG SỐ KỸ THUẬT Series B2900A Sourcemeter Function Current Measure, Voltage Measure Number of Channels 1 Source Voltage Range 210 (...
View full details -
0₫| /
Keithley 2450 Sourcemeter + WiFi Microscope, 1 Ch, 20 Ω → 200 MΩ ±10 nA → ±1 A [2450+MICFIP]; 125-0640
KeithleyTHÔNG SỐ KỸ THUẬT Series 2400 Sourcemeter Function Current Resistance Voltage Measure, Current Voltage Source Number of Channels 1 So...
View full details -
0₫| /
Keithley 2425 Sourcemeter, 1 Ch, 0.2 Ω → 200 MΩ ±10 μA → ±3 A ±200 mV → ±100 V 1000 W [2425]; 796-2674
KeithleyTHÔNG SỐ KỸ THUẬT Series 2400 Sourcemeter Function Current Resistance Voltage Measure, Current Voltage Source Number of Channels 1 So...
View full details