Skip to content

HƯỚNG DẪN MUA HÀNG qua Điện thoại / Email

Website đang trong giai đoạn xây dựng. Thông tin liên hệ: tổng đài 0898.332.898 hoặc E-mail: Sales@nguyenxuong.com

HƯỚNG DẪN MUA HÀNG qua Điện thoại / Email

. Thông tin liên hệ: tổng đài 0898.332.898 hoặc E-mail: Sales@nguyenxuong.com

Disconnects > Disconnects

Panduit Wire Termination, [DNFR18-206FIB-M]; PAI652

by Panduit
5.500₫
(Giá chưa VAT).
Mã kho: PAI652

Mã nhà sản xuất: DNFR18-206FIB-M

Đơn vị tính: PC

Quy cách đóng gói: 1,000

Liên hệ để có giá tốt (Vietnam: 0898.332.898,  E-mail: SKF@nguyenxuong.com)

Wire Termination / Terminals Terminal Kits / Disconnects: Panduit DNFR18-206FIB-M

MÔ TẢ SẢN PHẨM

The vibration resistant, right angle style female disconnect is made of brass and is tin-plated. It is fully insulated in red nylon. It has a tab size of 0.205/0.187 x 0.020 (5.2/4.7 x 0.5 mm) and supports a wire range of 22-18 AWG (0.5-1.0 mm²). It is 0.58" (14.7 mm) long, 0.37" (9.4 mm) wide, and

_THÔNG SỐ KỸ THUẬT:

Disconnect Type Female Disconnect-Right Angle
Insulation Material Vinyl - Fully Insulated
Maximum Copper Conductor Size (AWG) #18
Maximum Wire Size (AWG) #18
Minimum Wire Size (AWG) #22
Minimum Copper Conductor Size (AWG) #22
Wire Strip Length (In.) 0.28
Wire Strip Length (mm) 7.1
Tab Size (In.) 0.21
Tab Size (mm) 5.2
Standards Met UL 310 Listed, UL Listed 20H3 E78522; CSA Certified LR31212, C22.2 No.153
Maximum Voltage (V) 600
Base Material Brass
Finish/Coating Tinned
Color Code Red
Flammability Rating HB
Insulation Diameter (In.) 0.18
Insulation Diameter (mm) 4.6
Maximum Operating Temperature (°C) 105
Maximum Operating Temperature (°F) 221
Sub Brand Pan-Term
Maximum Wire Insulation Diameter (In.) 0.17
Maximum Wire Insulation Diameter (mm) 4.5
Overall Depth (In.) 0.6
Overall Depth (mm) 15.2
Overall Height (In.) 0.6
Overall Height (mm) 15.2
Overall Length (In.) 0.58
Overall Length (mm) 14.7
Overall Width (In.) 0.37
Overall Width (mm) 9.4
Seam Type Butted
Packaging Type Box
Product Type Loose Piece Disconnect
For Use With CT-300-1
Maximum Voltage (kV) 0.6
Part Features • Right angle design for use in limited space applications • Fully insulated design provides protection from electrical shorts • Internal wire stop assures proper length of insertion into terminal barrel, providing a higher quality connection • Disconnect can be inserted and removed from the male tab without the use of tools for lower installed cost • UL Flammability UL 94V-2/HB, maximum insulation temperature 221°F (105°C) • UL and CSA rated up to 600 V per UL 310