Skip to content

HƯỚNG DẪN MUA HÀNG qua Điện thoại / Email

Website đang trong giai đoạn xây dựng. Thông tin liên hệ: tổng đài 0898.332.898 hoặc E-mail: Sales@nguyenxuong.com

HƯỚNG DẪN MUA HÀNG qua Điện thoại / Email

. Thông tin liên hệ: tổng đài 0898.332.898 hoặc E-mail: Sales@nguyenxuong.com

Disconnects > Disconnects

Panduit Wire Termination, [DNF18-206-M]; PAI621

by Panduit
3.910₫
(Giá chưa VAT).
Mã kho: PAI621

Mã nhà sản xuất: DNF18-206-M

Quy cách đóng gói: 1,000

Liên hệ để có giá tốt (Vietnam: 0898.332.898,  E-mail: SKF@nguyenxuong.com)

Wire Termination / Terminals Terminal Kits / Disconnects: Panduit DNF18-206-M

MÔ TẢ SẢN PHẨM

The vibration resistant female disconnect is made of brass and is tin-plated. It is barrel insulated in a red, nylon housing. It has a tab size of 0.205/0.187 x 0.020" (5.2/4.7 x 0.5 mm) and supports a wire range of 22-18 AWG (0.5-1.0 mm²). It is 0.76" (19.3 mm) long and 0.25" (6.4 mm) wide. The dis

_THÔNG SỐ KỸ THUẬT:

Disconnect Type Female Disconnect
Insulation Material Nylon - Barrel Insulated
Maximum Copper Conductor Size (AWG) #22
Maximum Wire Size (AWG) #22
Minimum Wire Size (AWG) #18
Minimum Copper Conductor Size (AWG) #18
Wire Strip Length (In.) 0.28
Wire Strip Length (mm) 7.1
Tab Size (In.) 0.21
Tab Size (mm) 5.2
Standards Met UL 310 Listed, UL Listed 20H3 E78522; CSA Certified LR31212, C22.2 No.153
Maximum Voltage (V) 300
Base Material Brass
Finish/Coating Tinned
Color Code Red
Barrel Type Grip Sleeve
Flammability Rating HB
Insulation Diameter (In.) 0.14
Insulation Diameter (mm) 3.5
Maximum Operating Temperature (°C) 90
Maximum Operating Temperature (°F) 194
Sub Brand Pan-Term
Maximum Wire Insulation Diameter (In.) 0.14
Maximum Wire Insulation Diameter (mm) 3.5
Overall Height (In.) 0.12
Overall Height (mm) 3
Overall Length (In.) 0.76
Overall Length (mm) 19.3
Overall Thickness (In.) 0.16
Overall Thickness (mm) 0.4
Overall Width (In.) 0.25
Overall Width (mm) 6.4
Packaging Type Box
Product Type Loose Piece Disconnect
For Use With CT-500, CT-100, CT-160, CT-260, CT-550, CT-1550, CT-155
Maximum Voltage (kV) 0.3
Part Features • Disconnect can be inserted and removed from the male tab without the use of tools for lower installed cost • Metal insulation grip sleeve crimps to wire insulation, providing protection to the crimp joint during high vibration applications • Internal barrel serrations assure good wire contact and maximum tensile strength • Internal wire stop assures proper length of insertion into terminal barrel, providing a higher quality connection • UL Flammability UL 94V-2/HB, maximum insulation temperature 194°F (90°C) • UL and CSA rated up to 300 V per UL 310, where applicable