Panduit Wire Termination, [DNF14250FIMX-2K]; PAI612

by Panduit
10.700₫
(Giá chưa VAT).
Mã kho: PAI612

Mã nhà sản xuất: DNF14250FIMX-2K

Đơn vị tính: KT

Quy cách đóng gói: 2,000

Liên hệ để có giá tốt (Vietnam: 0898.332.898,  E-mail: SKF@nguyenxuong.com)

Wire Termination / Terminals Terminal Kits / Disconnects: Panduit DNF14250FIMX-2K

MÔ TẢ SẢN PHẨM

The vibration resistant male tab disconnect is made of brass and is nickel-plated. It is fully insulated in a blue, nylon standard housing and has an expanded wire entry area for wires with large outside diameters. It has a tab size of 0.250 x 0.032" (6.3 x 0.8 mm) and supports a wire range of 16-14

_THÔNG SỐ KỸ THUẬT:

Disconnect Type Male Tab Disconnect
Insulation Material Nylon - Barrel Insulated
Maximum Copper Conductor Size (AWG) #14
Maximum Wire Size (AWG) #14
Minimum Wire Size (AWG) #16
Minimum Copper Conductor Size (AWG) #16
Wire Strip Length (In.) 0.28
Wire Strip Length (mm) 7.1
Tab Size (In.) 0.25
Tab Size (mm) 6.3
Standards Met UL 310 Listed, UL Listed 20H3 E78522; CSA Certified LR31212, C22.2 No.153
Maximum Voltage (V) 600
Base Material Brass
Finish/Coating Nickel
Color Code Blue
Flammability Rating HB
Insulation Diameter (In.) 0.24
Insulation Diameter (mm) 6.2
Maximum Operating Temperature (°C) 105
Maximum Operating Temperature (°F) 221
Sub Brand Reel Smart
Maximum Wire Insulation Diameter (In.) 0.24
Maximum Wire Insulation Diameter (mm) 6.1
Overall Height (In.) 0.29
Overall Height (mm) 7.4
Overall Length (In.) 0.97
Overall Length (mm) 24.6
Overall Width (In.) 0.41
Overall Width (mm) 10.4
Seam Type Butted
Packaging Type Reel
Product Type Disconnects on a Reel
For Use With CD9-8B, CD-800-8
Maximum Voltage (kV) 0.6
Part Features • Continuously molded design provides reliable, consistent performance through the applicator for a high quality termination every time • Expanded wire entry designed to accommodate wire with a larger insulation thickness • Male tab couples with (all 0.250 x 0.032) female disconnects • Fully insulated design provides protection from electrical shorts • Male tab can be inserted and removed from the female disconnect without the use of tools for lower installed cost • Internal barrel serrations assure good wire contact and maximum tensile strength • UL Flammability UL 94V-2/HB, maximum insulation temperature 221°F (105°C) • UL and CSA rated up to 600 V per UL 310, where applicable